ULTRA WHISPER SPECIFICATIONS
|
 |
Performance:
Rated Performance / Product Water Produced: +-15% at 850 PSI /
56 BAR, 77oF / 25oC & 35,000 PPM TDS
typical sea water
|
Model # |
Per Hour |
Per Day |
UW 200
UW 300
UW 400
UW 500
UW 600 |
8.3
gal/31.5 lit
12.5 gal/47.3 lit
16.7 gal/63.1 lit
20.8 gal/78.9 lit
25 gal/94.6 lit |
200 gal
/757 lit
300 gal/1,136 lit
400 gal/1,514 lit
500 gal/1,893 lit
600 gal/2,271 lit |
Salt Rejection (Chloride Ion):
Minimum 99.2%, Average 99.4%
Product Water Temperature: Ambient to feed water
temperature
Salinity Monitoring: Automatic computer controlled
electronic monitoring. Temperature compensated with the Water
Quality Indicator. The salinity monitoring components of the
system give a continuous readout in micromhos per cubic
centimeter, are temperature compensated, and of a fail-safe
design.
Salinity Range: Designed for Seawater use up to 50,000
PPM TDS (NaCl)
(typical seawater salinity is 35,000 ppm)
Temperature Range: Max. 122oF / 50oC,
Min. 33oF / .5oC
Reverse Osmosis Membrane: Selected High Rejection/High
Yield aromatic tri-polyamid, thin film composite, spiral wound,
single pass, high rejection reverse osmosis membrane element.
Chlorine Tolerance: 0.1 PPM
pH Range: 3-11 (typical seawater pH is 8)
System Pressure:
Feed Water From The Feed Water Pump
Inlet to the Energy Transfer Device:
Nominal at 35,000 ppm TDS feed water salinity and 77oF /
25oC
UW
200
UW
300
UW
400
UW
500
UW
600 |
100 psi / 6.90 bar / 7.03
Kg/cm2 / 689.5 kPa
110 psi / 7.58 bar / 7.73 Kg/cm2 / 758.5 kPa
110 psi / 7.58 bar / 7.73 Kg/cm2 / 758.5 kPa
150 psi / 10.34 bar / 10.55 Kg/cm2 / 1,034.3
kPa
160 psi / 11.03 bar / 11.25 Kg/cm2 / 1,103.2
kPa |
Operation Pressure at the
R.O. Membrane Element:
Nominal at 35,000 ppm TDS feed water salinity and 77oF /
25oC
UW
200
UW
300
UW
400
UW
500
UW
600 |
600 psi / 41.37 bar / 42.18
Kg/cm2 / 4,137 kPa
625 psi / 43.09 bar / 43.94 Kg/cm2 / 4,309
kPa
625 psi / 43.09 bar / 43.94 Kg/cm2 / 4,309
kPa
765 psi / 52.75 bar / 53.78 Kg/cm2 / 5,275
kPa
825 psi / 56.88 bar / 58.00 Kg/cm2 / 5,688
kPa |
Weight:
|
Model Number
|
|
Compact
|
UW 200
UW 300
UW 400
UW 500
UW 600
|
130 lbs / 59 Kg
138 lbs / 63 Kg
145 lbs / 66 Kg
153 lbs / 69 Kg
155 lbs / 70 Kg |
135 lbs / 61 Kg
143 lbs / 65 Kg
150 lbs / 68 Kg
158 lbs / 72 Kg
160 lbs / 73 Kg |
External Installation Water Connections: Pipe sizes to be
supplied by the installer for connection of the Sea Recovery
supplied components. The below pipe threads are all American
Standard.
|
Feed Inlet: |
1/2" MNPT
Male National Pipe Thread |
| Brine Discharge: |
1/2" MNPT Male National
Pipe Thread |
| Product: |
1/4" FNPT Female
National Pipe Thread |
Electrical Power Specifications:
Nominal Operating Power Consumption in Amperes:
Amperes listed are nominal operating amperes when the feed
water conditions are 35,000 PPM TDS Salinity and 77oF
/ 25oC.
Power consumption will vary depending upon individual R.O.
Membrane Element, the condition of the R.O. Membrane
Element, Feed Water Temperature, and Feed Water Salinity.
| Model |
12 VDC |
24 VDC |
100-115
VAC |
220-230
VAC |
| UW 200 |
13 amps |
6.5 amps |
4.5 amps |
2.25 amps |
| UW 300 |
20 amps |
10 amps |
5 amps |
2.5 amps |
| UW 400 |
22 amps |
11 amps |
6.3 amps |
3.3 amps |
| UW 500 |
n/a |
18 amps |
8 amps |
4 amps |
| UW 600 |
n/a |
20 amps |
8.3 amps |
4.2 amps |
|
|